GPC KD-800 columns
Series with single-pore and mixed-gel columns
GPC columns prefilled with DMF
Product information
GPC KD-800
-
Standard organic solvent SEC (GPC) column
-
Supports a wide range of applications from low to high molecular weight compounds
-
Fulfills USP L21 requirements
-
Prefilled with DMF
-
Available as single-pore and mixed-bed
-
made to order
Mixed gel columns are packed with mixture of gels with different in pore size capable of analyzing samples over a wide range of molecular weight distribution. The mixed gel columns have "M" at the end of the column name.
The guard column is indicated with a "G": GPC KD-G 4A
2-3 columns can be coupled in row.
The solvent can be switched: Shodex GPC Columns Solvent Replacement Applicability 2022 (pdf)
Product overview
Product code | Product name | Separation | Functional group | Gel material | Plates per column | Particle size | Pore size | Size (ID x length) | Housing material |
---|---|---|---|---|---|---|---|---|---|
F6028210 | GPC KD-801 | GPC | - | Styrene divinylbenzene copolymer | ≥ 17,000 | 6 µm | 50 Å | 8.0 x 300 mm | steel |
F6028220 | GPC KD-802 | GPC | - | Styrene divinylbenzene copolymer | ≥ 17,000 | 6 µm | 150 Å | 8.0 x 300 mm | steel |
F6028225 | GPC KD-802.5 | GPC | - | Styrene divinylbenzene copolymer | ≥ 17,000 | 6 µm | 300 Å | 8.0 x 300 mm | steel |
F6028230 | GPC KD-803 | GPC | - | Styrene divinylbenzene copolymer | ≥ 17,000 | 6 µm | 500 Å | 8.0 x 300 mm | steel |
F6028240 | GPC KD-804 | GPC | - | Styrene divinylbenzene copolymer | ≥ 17,000 | 7 µm | 1,500 Å | 8.0 x 300 mm | steel |
F6028250 | GPC KD-805 | GPC | - | Styrene divinylbenzene copolymer | ≥ 11,000 | 10 µm | 5,000 Å | 8.0 x 300 mm | steel |
F6028260 | GPC KD-806 | GPC | - | Styrene divinylbenzene copolymer | ≥ 11,000 | 10 µm | 10,000 Å | 8.0 x 300 mm | steel |
F6028290 | GPC KD-806M | GPC | - | Styrene divinylbenzene copolymer | ≥ 13,000 | 10 µm | 10,000 Å | 8.0 x 300 mm | steel |
F6028270 | GPC KD-807 | GPC | - | Styrene divinylbenzene copolymer | ≥ 6,000 | 18 µm | 20,000 Å | 8.0 x 300 mm | steel |
F6700411 | GPC KD-G 4A | GPC | - | Styrene divinylbenzene copolymer | (guard) | 8 µm | - | 4.6 x 10 mm | steel |
Product details
Product name | Maximum pressure | Usual flow rate | Maximum flow rate | Temperature range | Shipping solvent | USP | MW range | Exclusion limit |
---|---|---|---|---|---|---|---|---|
GPC KD-801 | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | DMF | L21 | 100 - 1,500 | 2,500 |
GPC KD-802 | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | DMF | L21 | 200 - 4,000 | 7,000 |
GPC KD-802.5 | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | DMF | L21 | 400 - 10,000 | 20,000 |
GPC KD-803 | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | DMF | L21 | 1,000 - 50,000 | 70,000 |
GPC KD-804 | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | DMF | L21 | 4,000 - 200,000 | 200,000 |
GPC KD-805 | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | DMF | L21 | 30,000 - (4,000,000) | (4,000,000) |
GPC KD-806 | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | DMF | L21 | 30,000 - (40,000,000) | (40,000,000) |
GPC KD-806M | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | DMF | L21 | 1,000 - (40,000,000) | (40,000,000) |
GPC KD-807 | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | DMF | L21 | 50,000 - (200,000,000) | (200,000,000) |
GPC KD-G 4A | - | - | - | ≤ 60°C | DMF | L21 | - | - |
Product info
Applications
At the moment a new window opens and you are transferred to our Japanese website, when you click on the application. We are working on a better solution.
General
Calibration Curves for KD-800 Series (DMF Eluent: PEG, PEO)
Calibration Curves for KD-800 Series (DMF Eluent: PMMA)
Comparison of Calibration Curves for KD-800 Series and SB-800 HQ Series (DMF Eluent)
Comparison of Calibration Curves for KD-802.5 and SB-802.5 HQ (DMF Eluent: PEG, PEO and PS)
Columns
Amino Alcohols (1) (KD-802 + KD-801)
Cellulose Acetate (1) (KD-806M)
Cellulose Acetate (4) (DMF Eluent: Effects of LiBr Concentration) (KD-806M)
Corn Starch (3) (DMSO/DMF Eluent: KD-806M)
Ethylene Maleic Anhydride Copolymer (Comparison of KD-800 and SB-800 HQ)
Melamine-Formaldehyde Resin (DMF Eluent) (KD-802)
N-Vinylpyrrolidone Vinyl Acetate Copolymer (KD-806M)
Phenol Formaldehyde Resin (Comparison of KD-800 and SB-800 HQ)
Phenol Resin (2) (KD-803 + KD-802)
Poly(-N,N-Dimethylaminomethyl Styrene) (1) (DMF Eluent) (Comparison KD-800 with SB-800 HQ)
Poly(Ethylene Glycol) Standards (2) (DMF Eluent) (KD-802 + KD-801)
Poly(Ethylene Oxide) Standards (KD-806M + KD-802)
Polycarbonate Resin (2) (Comparison of SB-800 HQ and KD-800)
Polystyrene Standards (9) (KD-802)
Poly(vinylidene Fluoride) (KD-806M)
Polyvinylpyrrolidone (1) (DMF Eluent: KD-806M)
Polyvinylpyrrolidone (4) (DMF Eluent: Effects of LiBr Concentration) (KD-806M)
Potato Starch (DMSO/DMF Eluent: KD-806M)
Styrene Allylalcohol Copolymer (1) (KD-803 + KD-802)
Styrene Acrylonitrile Copolymer (1) (KD-806M)
Styrene Maleic Anhydride Copolymer (KD-806M)
Vinylidene Chloride Acrylonitrile Copolymer (1) (KD-806M)
Vinylidene Chloride Acrylonitrile Copolymer (2) (Comparison of KD-800 and SB-800 HQ)
Related products
The Shodex STANDARD S-Series is a calibration standard kit for organic size exclusion chromatography.
The Polystyrene (n = 4 to 200,000) is easily soluble in tetrahydrofuran (THF), chloroform, toluene, and o-dichlorobenzene (ODCB).
-
For organic solvent SEC (GPC)
-
Less branched polystyrene with anionic polymerization
STANDARD SL-105 Kit: 10 vials with 0.5 g each (for low MW)
MW 23.000, 13.000, 10.000, 6.500, 4.900, 2.900, 2.000, 1.200, 1.100, 600
STANDARD SM-105 Kit: 10 vials with 0.5 g each (for medium MW)
MW 2.330.000, 1.700.000, 740.000, 321.000, 129.000, 57.000, 23.000, 6.500, 2.900, 1.200
STANDARD SH-75 Kit: 7 vials with 0.5 g each (for high MW)
MW 6.550.000, 3.550.000, 3.020.000, 2.330.000, 1.860.000, 885.000, 662.000
The Shodex STANDARD M-75 is Polymethylmethacrylate for SEC, and it is suitable for SEC using hexafluoroisopropanol (HFIP) and dimethylformamide (DMF) solvent. Other usable solvents are tetrahydrofuran (THF), toluene, methyl ethyl ketone, ethyl acetate, DMF, and DMAc.
-
For organic solvent SEC (GPC)
-
Narrow molecular weight distribution range
Note: Molecular weights (Mp, Mw/Mn) of a standard kit or each single type may vary depending on production lots. Always refer to the inspection certificate.
STANDARD M-75 Kit: 7 vials with 0.5 g each.