GPC KF-800 and KF-400 columns
Series with single-pore and mixed-gel columns
The classical GPC column (in THF) for many general applications
Product information
GPC KF-800
-
Standard organic solvent SEC (GPC) column
-
Supports a wide range of applications from low to high molecular weight compounds
-
Fulfills USP L21 requirements
GPC KF-400HQ
-
About 1.5 times better separation performance than standard columns, obtains higher resolution
-
About 4 times better sensitivity than that of standard columns, supports high sensitivity analysis
-
The amount of solvent used is reduced to about a third
-
Improved applicability of solvent replacement
-
Fulfills USP L21 requirements
GPC KF-800D
Solvent-peak separation columns delay the elution of low-molecular components and can be used to separate a solvent peak or other troublesome peak to realize accurate measurement of molecular weight distribution. Use this column in combination with a linear column (GPC KF-805L, 806L, 806M, 807L).
Mixed gel columns are packed with mixture of gels with different in pore size capable of analyzing samples over a wide range of molecular weight distribution. The mixed gel columns have "M" at the end of the column name.
Linear type columns are also packed with mixture of gels capable of analyzing samples over a wider range of molecular weight distribution than the mixed gel columns. The linear type columns have "L" at the end of the column name.
The guard column is indicated with a "G": GPC KF-G 4A
2-3 columns can be coupled in row.
The solvent can be switched: Shodex GPC Solvent Replacement 2023 (pdf)
Can be used as alternative to Waters Styragel, Agilent PLgel, Phenomenex Phenogel, PSS SDV, and Tosoh Bioscience TSKgel H-type columns.
Product overview
Product code | Product name | Separation | Gel material | Plates per column | Particle size | Pore size | Size (ID x length) | Housing material |
---|---|---|---|---|---|---|---|---|
F6028010 | GPC KF-801 | GPC | Styrene divinylbenzene copolymer | ≥ 18,000 | 6 µm | 50 Å | 8.0 x 300 mm | steel |
F6028020 | GPC KF-802 | GPC | Styrene divinylbenzene copolymer | ≥ 18,000 | 6 µm | 150 Å | 8.0 x 300 mm | steel |
F6028025 | GPC KF-802.5 | GPC | Styrene divinylbenzene copolymer | ≥ 18,000 | 6 µm | 300 Å | 8.0 x 300 mm | steel |
F6028030 | GPC KF-803 | GPC | Styrene divinylbenzene copolymer | ≥ 18,000 | 6 µm | 500 Å | 8.0 x 300 mm | steel |
F6027030 | GPC KF-803L | GPC | Styrene divinylbenzene copolymer | ≥ 18,000 | 6 µm | 500 Å | 8.0 x 300 mm | steel |
F6028040 | GPC KF-804 | GPC | Styrene divinylbenzene copolymer | ≥ 18,000 | 7 µm | 1,500 Å | 8.0 x 300 mm | steel |
F6027040 | GPC KF-804L | GPC | Styrene divinylbenzene copolymer | ≥ 18,000 | 7 µm | 1,500 Å | 8.0 x 300 mm | steel |
F6028050 | GPC KF-805 | GPC | Styrene divinylbenzene copolymer | ≥ 11,000 | 10 µm | 5,000 Å | 8.0 x 300 mm | steel |
F6027050 | GPC KF-805L | GPC | Styrene divinylbenzene copolymer | ≥ 11,000 | 10 µm | 5,000 Å | 8.0 x 300 mm | steel |
F6027060 | GPC KF-806L | GPC | Styrene divinylbenzene copolymer | ≥ 13,000 | 10 µm | 10,000 Å | 8.0 x 300 mm | steel |
F6028090 | GPC KF-806M | GPC | Styrene divinylbenzene copolymer | ≥ 11,000 | 10 µm | 10,000 Å | 8.0 x 300 mm | steel |
F6027070 | GPC KF-807L | GPC | Styrene divinylbenzene copolymer | ≥ 6,000 | 18 µm | 20,000 Å | 8.0 x 300 mm | steel |
F6700300 | GPC KF-G 4A | GPC | Styrene divinylbenzene copolymer | (guard) | 8 µm | - | 4.6 x 10 mm | steel |
F6709350 | GPC KF-800D | GPC | Styrene divinylbenzene copolymer | - | 10 µm | - | 8.0 x 100 mm | steel |
Product code | Product name | Separation | Gel material | Plates per column | Particle size | Pore size | Size (ID x length) | Housing material |
---|---|---|---|---|---|---|---|---|
F6028111 | GPC KF-401 HQ | GPC | Styrene divinylbenzene copolymer | ≥ 25,000 | 3 µm | 50 Å | 4.6 x 250 mm | steel |
F6028112 | GPC KF-402 HQ | GPC | Styrene divinylbenzene copolymer | ≥ 25,000 | 3 µm | 150 Å | 4.6 x 250 mm | steel |
F6028114 | GPC KF-402.5 HQ | GPC | Styrene divinylbenzene copolymer | ≥ 25,000 | 3 µm | 300 Å | 4.6 x 250 mm | steel |
F6028116 | GPC KF-403 HQ | GPC | Styrene divinylbenzene copolymer | ≥ 25,000 | 3 µm | 500 Å | 4.6 x 250 mm | steel |
F6700300 | GPC KF-G 4A | GPC | Styrene divinylbenzene copolymer | (guard) | 8 µm | - | 4.6 x 10 mm | steel |
Product details
Product code | Product name | Maximum pressure | Usual flow rate | Maximum flow rate | Temperature range | Shipping solvent | USP | MW range | Exclusion limit |
---|---|---|---|---|---|---|---|---|---|
F6028010 | GPC KF-801 | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | THF | L21 | 100 - 700 | 1,500 |
F6028020 | GPC KF-802 | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | THF | L21 | 300 - 3,000 | 5,000 |
F6028025 | GPC KF-802.5 | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | THF | L21 | 300 - 8,000 | 20,000 |
F6028030 | GPC KF-803 | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | THF | L21 | 1,000 - 50,000 | 70,000 |
F6027030 | GPC KF-803L | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | THF | L21 | 100 - 50,000 | 70,000 |
F6028040 | GPC KF-804 | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | THF | L21 | 7,000 - 300,000 | 400,000 |
F6027040 | GPC KF-804L | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | THF | L21 | 100 - 300,000 | 400,000 |
F6028050 | GPC KF-805 | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | THF | L21 | 50,000 - 2,000,000 | 4,000,000 |
F6027050 | GPC KF-805L | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | THF | L21 | 300 - 2,000,000 | 4,000,000 |
F6027060 | GPC KF-806L | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | THF | L21 | 1,000 - (20,000,000) | (20,000,000) |
F6028090 | GPC KF-806M | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | THF | L21 | 300 - (20,000,000) | (20,000,000) |
F6027070 | GPC KF-807L | 3.5 MPa (35 bar) | 0.5 to 1.0 mL/min | 2.0 mL/min | ≤ 60°C | THF | L21 | 300 - (200,000,000) | (200,000,000) |
F6700300 | GPC KF-G 4A | - | - | - | ≤ 60°C | THF | L21 | - | - |
F6709350 | GPC KF-800D | - | - | - | - | THF | L21 | solvent-peak separator | - |
Product code | Product name | Maximum pressure | Usual flow rate | Maximum flow rate | Temperature range | Shipping solvent | USP | MW range | Exclusion limit |
---|---|---|---|---|---|---|---|---|---|
F6028111 | GPC KF-401 HQ | 7 Mpa (70 bar) | 0.2 to 0.3 mL/min | 0.5 mL/min | ≤ 45°C | THF | L21 | 100 - 700 | 1,500 |
F6028112 | GPC KF-402 HQ | 7 Mpa (70 bar) | 0.2 to 0.3 mL/min | 0.5 mL/min | ≤ 45°C | THF | L21 | 200 - 1,500 | 4,000 |
F6028114 | GPC KF-402.5 HQ | 7 Mpa (70 bar) | 0.2 to 0.3 mL/min | 0.5 mL/min | ≤ 45°C | THF | L21 | 300 - 10,000 | 20,000 |
F6028116 | GPC KF-403 HQ | 7 Mpa (70 bar) | 0.2 to 0.3 mL/min | 0.5 mL/min | ≤ 45°C | THF | L21 | 600 - 50,000 | 70,000 |
F6700300 | GPC KF-G 4A | - | - | - | ≤ 60°C | THF | L21 | - | - |
Product info
Applications
At the moment a new window opens and you are transferred to our Japanese website, when you click on the application. We are working on a better solution.
General
Calibration Curves for KF-800 Series (THF Eluent: PS)
Calibration Curves for KF-800L Series (THF Eluent: PS)
Comparison of Calibration Curves: Linear Type and Conventional Type
Comparison of Separation: Linear Type and Conventional Type (1)
Comparison of Separation: Linear Type and Conventional Type (2)
Calibration Curves for KF-806L (Various Eluents: PS)
KF-801
Analysis of Propylene Glycol Monocaprylate According to USP-NF Method (KF-801)
Effects of Column Length on Elution Pattern (KF-801)
Fat-Soluble Vitamins (3) (KF-801)
Phthalates and Alkylbenzenes (1) (KF-801)
Poly(Ethylene Glycol) Standards (1) (THF Eluent) (KF-801)
Polystyrene Standards (1) (KF-801)
KF-802, KF-802.5
Analysis of Ethylcellulose Dispersion Type B According to USP-NF Method (KF-802)
Analysis of Glyceryl Distearate According to USP-NF Method (KF-802)
Analysis of Glyceryl Monolinoleate According to USP-NF Method (KF-802)
Analysis of Glyceryl Monooleate According to USP-NF Method (KF-802)
Analysis of Glyceryl Stearate According to USP-NF Method (KF-802)
Analysis of Glyceryl Tristearate According to USP-NF Method (KF-802)
Comparison of KF-402HQ and KF-802
Dimethyl Silicone Oil (Toluene Eluent)
Effects of Flow Rate (1) (KF-402HQ)
Effects of Flow Rate on Elution Pattern (KF-802)
Effects of Flow Rate on Plate Number
Effects of Pore Size on Separation
Epoxy Resin (5) (Comparison of HK and KF-800 Series Columns)
Epoxy Resin (6) (Comparison of HK-402 and KF-802.5)
Epoxy Resin Oligomer (KF-803 + KF-802.5)
Poly(Propylene Glycol) (KF-802.5)
Polystyrene Standards (10) (Toluene Eluent)
Polystyrene Standards (2) (KF-802)
KF-803 - KF-805L
1,2-Polybutadiene (1) (KF-805L)
Biodegradable Polymer (5) (Poly(Lactic-co-Glycolic Acid)) (KF-804L)
Comparison of HK-404L and KF-805L
Effects of Pore Size on Separation
Epoxy Resin (5) (Comparison of HK and KF-800 Series Columns)
Epoxy Resin Oligomer (KF-803 + KF-802.5)
Poly(2,4,6-tribromostyrene) (KF-805L)
Poly(Methyl Methacrylate) Standards (1) (KF-805L)
Polystyrene Standards (3) (KF-803L)
Polystyrene Standards (4) (KF-804L)
Polystyrene Standards (5) (KF-805L)
Styrene butyl methacrylate copolymer (1) (KF-805L)
Vinyl Chloride Vinyl Acetate Vinyl Alcohol Terpolymer (KF-805L)
Vinylidene Chloride Vinyl Chloride Copolymer (KF-805L)
KF-806L - KF-807L
Biodegradable Polymer (6) (Polylactic Acid) (KF-806M)
Butyl Methacrylate Isobutyl Methacrylate Copolymer (KF-806L)
Cellulose Acetate (3) (KF-806L)
Cellulose Acetate Butyrate (KF-806L)
Dextran (2) (DMSO Eluent) (KF-806M)
Dimethyl Silicone Oil (Toluene Eluent)
Effects of Solvent-Peak Separation Column on Calibration Curve
Effects of Solvent-peak Separation Column on Separation (1)
Effects of Solvent-Peak Separation Column on Separation (2)
Ethylene Vinyl Acetate Copolymer (1) (KF-806L)
GPC/MALS Analysis of Standard Polystyrene (KF-806L)
Methacrylic Acid Copolymer (KF-806M)
Poly(Butyl Methacrylate) (KF-806L)
Poly(Isobutyl Methacrylate) (KF-806L)
Poly(Methyl Methacrylate) Standards (2) (KF-806L)
Poly(Vinyl Butyral) (1) (KF-806L)
Poly(Vinyl Chloride) (KF-806M)
Poly(Vinyl Formal) (1) (KF-806L)
Polycarbonate Resin (1) (KF-806L)
Polystyrene Standards (10) (Toluene Eluent)
Polystyrene Standards (19) (DMAc Eluent)
Polystyrene Standards (20) (NMP Eluent)
Polystyrene Standards (6) (KF-806L)
Polystyrene Standards (7) (KF-807L)
Styrene Butadiene ABA Block Copolymer (KF-806M)
Styrene Ethylene Butylene ABA Block Copolymer (KF-806M)
Styrene Isoprene ABA Block Copolymer (KF-806M)
KF-800D solvent-peak separation
Effects of Solvent-Peak Separation Column on Calibration Curve
Related products
The Shodex STANDARD S-Series is a calibration standard kit for organic size exclusion chromatography.
The Polystyrene (n = 4 to 200,000) is easily soluble in tetrahydrofuran (THF), chloroform, toluene, and o-dichlorobenzene (ODCB).
-
For organic solvent SEC (GPC)
-
Less branched polystyrene with anionic polymerization
STANDARD SL-105 Kit: 10 vials with 0.5 g each (for low MW)
MW 23.000, 13.000, 10.000, 6.500, 4.900, 2.900, 2.000, 1.200, 1.100, 600
STANDARD SM-105 Kit: 10 vials with 0.5 g each (for medium MW)
MW 2.330.000, 1.700.000, 740.000, 321.000, 129.000, 57.000, 23.000, 6.500, 2.900, 1.200
STANDARD SH-75 Kit: 7 vials with 0.5 g each (for high MW)
MW 6.550.000, 3.550.000, 3.020.000, 2.330.000, 1.860.000, 885.000, 662.000
The Shodex STANDARD M-75 is Polymethylmethacrylate for SEC, and it is suitable for SEC using hexafluoroisopropanol (HFIP) and dimethylformamide (DMF) solvent. Other usable solvents are tetrahydrofuran (THF), toluene, methyl ethyl ketone, ethyl acetate, DMF, and DMAc.
-
For organic solvent SEC (GPC)
-
Narrow molecular weight distribution range
Note: Molecular weights (Mp, Mw/Mn) of a standard kit or each single type may vary depending on production lots. Always refer to the inspection certificate.
STANDARD M-75 Kit: 7 vials with 0.5 g each.