top of page

HILICpak VG-50 columns

with tertiary amino groups

The robust HILIC column for many general applications

Product information

  • Suitable for saccharide analysis using HILIC mode

  • Recovers reducing saccharides with high ratio (usage of tert. amine groups to avoid building of Schiff base)

  • Polymer-based packing material provides excellent chemical stability and minimum deterioration

    over an extended time period

  • pH stability: 2 to 13 (silanol free)

  • Easily regenerated by washing in an alkaline solution

  • Also suitable for evaporative light scattering detector (ELSD), corona charged aerosol detector (CAD), and mass spectrometry (LC-MS/MS)

Product overview

Product code
Product name
Separation
Functional group
Gel material
Plates per column
Particle size
Pore size
Size (ID x length)
Housing material
F7630200
HILICpak VG-50 4D
HILIC
Amino
Polyvinyl alcohol
≥ 5,500
5 µm
100 Å
4.6 x 150 mm
steel
F7630100
HILICpak VG-50 4E
HILIC
Amino
Polyvinyl alcohol
≥ 7,500
5 µm
100 Å
4.6 x 250 mm
steel
F6711100
HILICpak VG-50G 4A
HILIC
Amino
Polyvinyl alcohol
(guard)
5 µm
-
4.6 x 10 mm
steel
F7630300
HILICpak VG-50 2D
HILIC
Amino
Polyvinyl alcohol
≥ 3,500
5 µm
100 Å
2.0 x 150 mm
PEEK
F6711200
HILICpak VG-50G 2A
HILIC
Amino
Polyvinyl alcohol
(guard)
5 µm
-
2.0 x 10 mm
PEEK

Product details

Product name
Maximum pressure
Usual flow rate
Maximum flow rate
Temperature range
pH range
Shipping solvent
USP
HILICpak VG-50 4D
10 MPa (100 bar)
0.5 to 1.0 mL/min
1.5 mL/min
4 to 60°C
2 to 13
H2O/CH3CN = 20/80
-
HILICpak VG-50 4E
15 MPa (150 bar)
0.5 to 1.0 mL/min
1.5 mL/min
4 to 60°C
2 to 13
H2O/CH3CN = 20/80
-
HILICpak VG-50G 4A
-
0.5 to 1.0 mL/min
1.5 mL/min
4 to 60°C
2 to 13
H2O/CH3CN = 20/80
-
HILICpak VG-50 2D
15 MPa (150 bar)
0.1 to 0.2 mL/min
0.45 mL/min
4 to 60°C
2 to 13
H2O/CH3CN = 15/85
-
HILICpak VG-50G 2A
-
0.1 to 0.2 mL/min
0.45 mL/min
4 to 60°C
2 to 13
H2O/CH3CN = 15/85
-

Products

Applications

At the moment a new window opens and you are transferred to our Japanese website, when you click on the application. We are working on a better solution.

TESTIMONIALS

Great unique sugar column

Review date: 31 Oct 2017 | HILICpak VG-50 4E

 

Application Area: Analyze sugars in food products

"One of our most used columns in our laboratory for the last year. Good separation, long life and reproducible results. This unique column separate all the sugars needed for our diary product analysis, even the glucose/galactose pair which is usually very hard to separate. At last, after using a lot of "sugar" columns, we found the one! This column is also fits well our CAD detector which needs a non bleeding column. Although not so cheap, it has a great value for money."
Ronny Dayag / Tnuva on www.selectscience.net

bottom of page