top of page

HILICpak VN-50 columns

with diol groups

The robust HILIC column for oligosaccharides and oligonucleotides

Product information

  • The modified diol groups on the packing material create the HILIC mode

  • Suitable for oligosaccharide and oligonucleotide separation which is not possible by SEC column or conventional HILIC columns

  • Polymer-based packing material provides excellent chemical stability and minimum deterioration over an extended time period

  • pH stability: 2 to 13 (silanol free)

  • Easily regenerated by washing in an alkaline solution

  • Also suitable for evaporative light scattering detector (ELSD), corona charged aerosol detector (CAD), and mass spectrometry (LC-MS/MS)

  • New size HILICpak VN-50 1D adopts a double structure housing with an outer surface made of SUS and an inner surface [wetted part] made of PEEK. Covers the weak point of physical strength of PEEK housing and can be used under high pressure conditions. It has an inner diameter of 1.0 mm, which makes it possible to suppress the flow rate to 0.1 mL/min or less, so it suitable for high sensitivity analysis by LC/MS.

Product overview

Product code
Product name
Separation
Functional group
Gel material
Plates per column
Particle size
Pore size
Size (ID x length)
Housing material
F7630500
HILICpak VN-50 4D
HILIC
Diol
Polyvinyl alcohol
≥ 10,000
5 µm
100 Å
4.6 x 150 mm
PEEK
F6711400
HILICpak VN-50G 4A
HILIC
Diol
Polyvinyl alcohol
(guard)
5 µm
-
4.6 x 10 mm
PEEK
F7630600
HILICpak VN-50 2D
HILIC
Diol
Polyvinyl alcohol
≥ 3,500
5 µm
100 Å
2.0 x 150 mm
PEEK
F6711500
HILICpak VN-50G 2A
HILIC
Diol
Polyvinyl alcohol
(guard)
5 µm
-
2.0 x 10 mm
PEEK
F7630800
HILICpak VN-50 1D
HILIC
Diol
Polyvinyl alcohol
≥ 2,800
5 µm
100 Å
1.0 x 150 mm
PEEK
F6830100
HILICpak VN-50 10E
HILIC
Diol
Polyvinyl alcohol
≥ 11,000
5 µm
100 Å
10.0 x 250 mm
steel

Product details

Product name
Maximum pressure
Usual flow rate
Maximum flow rate
Temperature range
pH range
Shipping solvent
USP
HILICpak VN-50 4D
10 MPa (100 bar)
0.3 to 1.0 mL/min
1.5 mL/min
4 to 60°C
2 to 13
H2O/CH3CN = 25/75
-
HILICpak VN-50G 4A
-
0.3 to 1.0 mL/min
1.5 mL/min
4 to 60°C
2 to 13
H2O/CH3CN = 25/75
-
HILICpak VN-50 2D
10 MPa (100 bar)
0.1 to 0.3 mL/min
0.5 mL/min
4 to 60°C
2 to 13
H2O/CH3CN = 25/75
-
HILICpak VN-50G 2A
-
0.05 to 0.3 mL/min
0.5 mL/min
4 to 60°C
2 to 13
H2O/CH3CN = 25/75
-
HILICpak VN-50 1D
10 MPa (100 bar)
0.01 to 0.05 mL/min
0.1 mL/min
4 to 60°C
2 to 13
H2O/CH3CN = 25/75
-
HILICpak VN-50 10E
15 MPa (150 bar)
2.0 to 3.0 mL/min
5.0 mL/min
4 to 60°C
2 to 13
H2O/CH3CN = 25/75
-

Product info

Applications

At the moment a new window opens and you are transferred to our Japanese website, when you click on the application. We are working on a better solution.

bottom of page